Temperature, Transmitters, Rtds, Thermocouples Sensors Calibration

Submitted by • May 31, 2018

For Temperature Parameter covers the Range from -95 o +1200 Deg: All type of temperature sensors, Gauges, Ultra Cool Deep Freezer - 192 to 50 Degrees. Using the High Stability Temperature Source of Fluke make 9190 and 9150 and ...

Pure Steam Validation

Submitted by • May 29, 2018

Steam quality test equipment to qualify plant/utility/clean/pure steam generators, steam distribution systems and steam supplies to autoclaves in accordance with cGMP (Orange Guide), HTM 01, HTM 2010 (replaced by CFPP01-0l): 1994, HTM 2031 (replaced by CFPP01-0l): 1997, EN 285: 2006, ...

Ware House Mapping Validation

Submitted by • May 28, 2018

Umed offers a complete Temperature & RH mapping service for any finished product - Raw material warehouse -Production rooms - cold facility in compliance with regulatory guidelines to comply with current guidelines, mapping of a warehouse must be ...

Temperature & Rh Measurement

Submitted by • May 28, 2018

We conduct validation tests that include Temperature and Humidity Measurements for Production, Warehouse, to ensure that the clean room's HVAC system maintains the specified levels of temperature and humidity required for occupant comfort. The second level or the comprehensive level ...

Procedure For Operation Calibration And Maintenance Of Incubators

Procedure For Operation Calibration And Maintenance Of Incubators

Submitted by • April 19, 2018

ichapps.com - To lay down the procedure for operation, calibration and maintenance of incubators. This procedure applies to incubators used in microbiology for incubation at required temperatures respectively with the following details. The responsibility of proper operation, calibration and maintenance of incubators ...

Procedure To Test The Efficacy Of UV Lamp Against Microbial Challenge

Procedure To Test The Efficacy Of UV Lamp Against Microbial Challenge

Submitted by • April 16, 2018

ichapps.com - To lay down the Procedure to test the efficacy of UV lamp against microbial challenge. This procedure applies to UV lamps of Pass box, Laminar Air Flow bench and Garments box located in the microbiology area. The responsibility of ...

Procedure For Isolation Identification And Gram Staining Of Microorganisms

Procedure For Isolation Identification And Gram Staining Of Microorganisms

Submitted by • April 16, 2018

ichapps.com - To lay down the Procedure for Isolation,Identification and Gram Staining of Microorganisms. This procedure applies to isolation, identification and gram staining of microorganisms during the course of regular microbiological analysis. The responsibility of isolation, identification and gram staining of microorganisms ...

Replacement Of Oil Seals Of Gear Boxes

Replacement Of Oil Seals Of Gear Boxes

Submitted by • March 15, 2018

ichapps.com - To describe a standard operating procedure for replacement of oil seals of gear boxes. The standard operating procedure describes in detail the method of replacing oil seals of gear boxes belongs to Process / Utilities / Laboratory equipments. The responsibility ...

Replacement Of Bearings Of Process Utilities Laboratory Equipment

Replacement Of Bearings Of Process Utilities Laboratory Equipment

Submitted by • March 15, 2018

ichapps.com - To describe a standard operating procedure for replacement of bearings of process / utilities / laboratory equipment. The standard operating procedure describes in detail the method of replacing the bearings of process / utilities / laboratory equipment. The responsibility of ...

Replacement Of Coupling Bolts Of Reactors

Replacement Of Coupling Bolts Of Reactors

Submitted by • March 15, 2018

ichapps.com - To describe a standard operating procedure for replacement of coupling bolts of reactors. The standard operating procedure describes in detail the method of replacing coupling bolts of reactors. The responsibility of replacing the coupling bolts of reactors lies with the ...